replacing defective venous valve with implant
Last Updated : GMT 06:49:16
Arab Today, arab today
Arab Today, arab today
Last Updated : GMT 06:49:16
Arab Today, arab today

Replacing defective venous valve with implant

Arab Today, arab today

Arab Today, arab today Replacing defective venous valve with implant

London - Arabstoday

If heart valves don't close properly, they are replaced. Conventional treatment of venous valve failure, however, has up to now always and exclusively been via medication. In future, an implant will assume the function of damaged valves - and a new dispensing tool means these prostheses can be made using an automated process. It's one of the most commonly occurring medical conditions - chronic venous in-sufficiency (CVI). Almost ten million German citizens suffer from weak veins that require treatment, with twice as many women being affected as men. The cause of this widespread condition is restricted functioning of the venous valves in the legs. If the venous valve is no longer able to close properly, blood will observe the laws of gravity in between heartbeats and flow down to collect in the legs. This leads to edemas, and can cause open ulcers in particularly severe cases. CVI is usually treated with anti-inflammatory drugs and diuretics; as yet there is no globally available venous valve implant that can be used to treat the illness. This is something that researchers from the Fraunhofer Institute for Manufacturing Engineering and Automation IPA in Stuttgart are setting out to change: In close collaboration with four industrial partners and Helmholtz-Institute for Biomedical Engineering of RWTH Aachen University, they have developed an automated production facility that can make venous valve prostheses from polycarbonate-urethane (PCU), a plastic. The project was sponsored by the German Federal Ministry of Economics and Technology BMWI. The centerpiece of the facility is a 3D droplet dispensing tool which enables the researchers to precisely apply a particular polymer onto freeform surfaces and at the same time combine various grades of polymer hardness, called Shore hardnesses. "3D droplet dispensing technology is an additive procedure that allows three-dimensional geometries to be created layer by layer using a polymer", explains Dr. Oliver Schwarz, group manager at the IPA. The scientists use PCU because it is particularly strong and flexible, while another useful property of the material is that it is easy to sew into surrounding tissue. PCU structures can be made in very thin layers, which is ideal when replacing wafer-thin atrioventricular valves. "By using PCU in combination with our 3D dispensing kinematics, we can achieve seamless transitions within the material between six different grades of elasticity and hardness - without any breaking points whatsoever. This technique mirrors the design of highly stressed structures in nature. It can't be done using injection molding", says Schwarz. But how does the PCU become a venous valve prosthesis? Initially, the polymers are dissolved in a solvent and deposited onto a venous valve prosthetic mold one droplet at a time, using the dispensing tool. The system is accurate to within 25 micrometers, and can deliver up to 100 droplets per second, each with a volume of 2 to 60 nanoliters. A six-axis kinematic system positions the piezo feeder precisely above the mold. Once it is fully coated with droplets, the mold is bathed in a warm stream of nitrogen. This causes the solvent to evaporate, leaving the polymer behind. Further layers are applied by repeating the dispensing process, and in the end the polymer prosthesis can simply be peeled from the mold. Doctors can take the finished replacement valves and implant them into the veins of the leg via a catheter passed through the skin.

arabstoday
arabstoday

Name *

E-mail *

Comment Title*

Comment *

: Characters Left

Mandatory *

Terms of use

Publishing Terms: Not to offend the author, or to persons or sanctities or attacking religions or divine self. And stay away from sectarian and racial incitement and insults.

I agree with the Terms of Use

Security Code*

replacing defective venous valve with implant replacing defective venous valve with implant

 



Name *

E-mail *

Comment Title*

Comment *

: Characters Left

Mandatory *

Terms of use

Publishing Terms: Not to offend the author, or to persons or sanctities or attacking religions or divine self. And stay away from sectarian and racial incitement and insults.

I agree with the Terms of Use

Security Code*

replacing defective venous valve with implant replacing defective venous valve with implant

 



GMT 20:57 2017 Tuesday ,14 February

China to avoid bank shock, reach high income

GMT 14:11 2017 Friday ,18 August

Infosys chief quits in rift with founders

GMT 11:08 2017 Saturday ,16 September

German union attacks Air Berlin administrators for delay

GMT 19:59 2017 Saturday ,21 October

Mufti condemns Afghan mosque attacks

GMT 05:33 2016 Sunday ,18 December

Oil tanker catches fire on Super Highway, 3 killed

GMT 16:15 2017 Tuesday ,11 July

IEA: Oil, gas investment set to recover slightly

GMT 09:12 2018 Wednesday ,12 December

Ford trains 1,600 motorists in Mideast, Africa in 2018

GMT 18:29 2013 Friday ,08 March

Cheb Khaled tops best French song list

GMT 14:22 2018 Saturday ,20 January

Hariri meets French Foreign Minister

GMT 06:33 2017 Sunday ,31 December

Gazan dies after border clash with Israel forces
Arab Today, arab today
 
 Arab Today Facebook,arab today facebook  Arab Today Twitter,arab today twitter Arab Today Rss,arab today rss  Arab Today Youtube,arab today youtube  Arab Today Youtube,arab today youtube

Maintained and developed by Arabs Today Group SAL.
All rights reserved to Arab Today Media Group 2021 ©

Maintained and developed by Arabs Today Group SAL.
All rights reserved to Arab Today Media Group 2021 ©

arabstoday arabstoday arabstoday arabstoday
arabstoday arabstoday arabstoday
arabstoday
بناية النخيل - رأس النبع _ خلف السفارة الفرنسية _بيروت - لبنان
arabstoday, Arabstoday, Arabstoday